The ECHOES training in five-minute lessons
The ECHOES Sustainable Toolkit Training runs online from July 2026 to spring 2027 for venue staff and independent event organisers across Europe. Each evening holds two separate 30-minute sessions, each a complete lesson with its own objectives, its own toolkit pages and its own field task. This page gives the essence of every session delivered so far: what it teaches, the numbers to remember, one thing you can do this week, and where to read more in the toolkit. New sections are added after each session.
The printed Sustainability Toolkit (June 2026) is the reference document; page numbers below are the ones printed at the bottom of each page. The Interactive Toolkit and the Carbon Calculator on this site work alongside it. To join the live sessions, apply through the Training Program page.
Choose a session below to open its five-minute lesson. The two sessions of 24 November appear here after they are delivered.
Delivered 28 July 2026 · 75 minutes · Toolkit basis: Introduction, Quick Start: Your First 30 Days, Annex A (Strategic Self-Assessment)
In five minutes
- The programme is nine evenings with a field task between each pair of sessions, a Practical Tasks Companion that holds the tasks, and a peer-learning network that continues after the last session. Short input, a lot of doing.
- Where live-music emissions come from: audience travel first (62% of the total in the US, 77% in the UK), food and beverage second (16.9% US, 7.6% UK). Source: the MIT Climate Machine 2025 baseline, over 80,000 events, US and UK only. Venue energy is the largest source a venue fully controls.
- Honest numbers: a headline such as a major tour's 59% reduction is a tour figure, measured with audience travel excluded. It is not a venue benchmark. Realistic first-year venue targets are a 15 to 25% energy reduction, 50% waste diversion and a measurable shift in how the audience travels.
- Annex A is your "before photo": a strategic self-assessment scored row by row, from 0 (not started) to 5 (industry leadership). Honest zeros beat optimistic threes; a question mark where you do not know is useful data. The same scorecard is re-scored in Session 9.
- Quick Start, five actions for the first 30 days: a green tariff, two plant-forward bar items, three-stream waste sorting, faucet aerators, a Visual Schedule and Sensory Map for accessibility.
One thing to do this week (Field Task 1, under two hours)
Complete every row of Annex A. Choose two of the five Quick Start actions and take their first concrete step. Read one number off your last electricity bill: monthly consumption in kWh. No venue of your own? Adopt the venue closest to you as a desk study and mark what you cannot find out with a question mark.
Go deeper: Toolkit Introduction and Quick Start pages; Annex A; the self-assessment section of the Interactive Toolkit.
Delivered 29 September 2026 · 30 minutes · Toolkit Module 1.1 and 1.2, pages 9 to 11 · Field Task 2
In five minutes
- Three uses carry most of a venue's electricity: lighting, heating and cooling, and equipment left on. The session's first question is which one you will check first in your own building.
- Your bill holds three numbers you need: consumption in kWh, the price per kWh, and whether the supply is certified renewable. Everything else on the invoice can wait.
- What LED really saves depends on what you replace: halogen, HID or fluorescent fittings give very different savings, so the honest step is to estimate your current LED share and name the fittings that remain, before quoting a percentage. (Module 1.1)
- Phantom draw, the equipment that stays on after everyone has gone home, can account for up to around 10% of consumption, and it costs nothing to eliminate except attention. (Companion, Field Task 2)
- You can start measuring on Monday at zero cost: read the meter on a quiet day and on an event day, write both down with the date. Two readings are the beginning of a baseline. Resilient power (Module 1.2, battery and hybrid systems) is a question for later and for larger venues.
One thing to do this week (Field Task 2, about 1.5 hours)
After closing or load-out, walk the whole venue and list everything still drawing power; aim for at least five items. Estimate the share of lighting already LED and note what the rest is. Check whether the heating and cooling schedule follows your event calendar or the clock.
Go deeper: Toolkit pages 9 to 11; Field Task 2 on page 50; the energy module of the Interactive Toolkit.
Delivered 29 September 2026 · 30 minutes · Toolkit Module 1.3, Annex K (page 40), Creative Innovation Layer ideas 5 and 8
In five minutes
- A booking becomes a load. Set length, amplification, screens, hall hours before and after the show: programming and scheduling decisions change the energy of an evening independently of the building. Two real evenings of the same organiser, one small acoustic night and one 600-seat hall concert, showed how far apart those loads sit. (figures as entered in the ECHOES calculator from the organiser's event reports, estimated)
- Five eco-concert formats from Module 1.3: an acoustic or electroacoustic set, an LED-candle night, a daytime "Golden Hour" session, a solar "Busker" set, rechargeable stage power. The session added a sixth of its own, the silent concert, labelled as outside the toolkit and unmeasured.
- Two production choices are inside your own control for the next booking, whatever the building allows: pick them, write them down, and keep them.
- Honest labels: say "entered", "estimated" or "measured" next to every number you publish, and never claim "carbon neutral" on borrowed figures. This is the toolkit's communication rule from the first session on.
- The Green Rider ladder (Annex K, page 40): Bronze, Silver and Gold levels of what a venue asks of a visiting act, and what it offers in return. The practical step is one question to one act about their rider.
One thing to do this week
Take one real upcoming booking. Write two production choices you control that reduce load, and send one rider question to the act. Then pick one eco-concert idea from Module 1.3 and note what its first trial would look like at your venue (Field Task 2, step 4).
Go deeper: Toolkit page 10 and Annex K on page 40; Creative Innovation Layer ideas 5 and 8.
Delivered 27 October 2026 · 30 minutes · Toolkit Module 1.4, pages 10 and 11 · Field Task 3 (Companion pages 6 and 7)
In five minutes
- One method underlies every module: treat the event as a temporary organisation, born at load-in and gone at load-out, and measure what happens in between. The method aligns with ISO 14064 and the GHG Protocol, so a verified number is possible later if a funder or a city asks. (page 10)
- Six steps: define the boundary; map the sources (energy, transport, materials, food and beverage, waste, accommodation); collect activity data in physical units (kWh, litres, passenger-km, kilograms); apply emission factors; report and verify; build a reduction plan, hot spots first. Sessions 3a and 3b are steps one to four on your own event.
- Three scopes: Scope 1, fuel you burn on site; Scope 2, electricity and heat you buy; Scope 3, everything the event causes outside your walls. For most events Scope 3, chiefly audience travel, is 70 to 85% of the total. (page 10)
- Two real evenings, side by side: a 55-person acoustic night where most people cycled, and a 600-person hall concert with an average audience journey of 25 km one way. In the first, food was the hot spot; in the second, audience travel. The hot spot depends on format and audience, so no two reduction plans look alike. (the kWh are the figures entered in the calculator; the modal split is an estimate, not a survey)
- The useful output of the session is a map: one event, its boundary, its sources by scope, and next to each source whether you hold the data, can get it, or cannot, and who holds it.
One thing to do this week (Field Task 3, first half)
Choose one recent, typical event. Draw its boundary from load-in to load-out. List its sources by scope, counting nothing yet. Mark each as "have it", "can get it" or "cannot", with the name of the person who holds it.
Go deeper: Toolkit pages 10 and 11; Companion pages 6 and 7; the carbon footprint section of the Interactive Toolkit.
Delivered 27 October 2026 · 30 minutes · Toolkit Module 1.4, page 11 · Field Task 3 worksheet (Companion pages 6 and 7)
In five minutes
- An emission factor turns a unit of activity into kilograms of CO2 equivalent. The table on page 11 gives indicative factors; "indicative" means good enough for your first footprint and for comparing your own events, and never a certified number.
- Every result carries three things next to it: the factor, its source and its publication date. Factors expire: national sets are revised yearly, grid factors fall as grids decarbonise, and flight factors changed substantially in 2025 because the method changed. A footprint without a date is a guess.
- The car trap: count car travel once, either per vehicle-km (the car, whoever is in it) or per passenger-km (each person in a shared car), never both for the same car.
- The 600-person hall concert worked by hand with the page 11 factors: electricity 180 kWh × 0.25 (Romania, lifecycle grid factor as printed) = 45 kg; audience travel by mode about 3,200 kg; waste 90 kg at 65% diverted, about 17 kg. Counted lines about 3,270 kg, 5.4 kg per attendee, audience travel 98% of it. The same evening with the spring 2026 calculator factors gave about 4,000 kg: the difference is the factor set, with no change in the event. (Figures as entered in the calculator; the modal split is an estimate.)
- The ECHOES Carbon Calculator (version 4.0, September 2026) does the arithmetic and names the factor set under its result. It no longer gives an A to E grade: the toolkit's rule is to compare an event with your own next event, never with a grade or another venue.
One thing to do this week (Field Task 3, second half)
Put numbers to the sources you mapped: kWh, litres, kilograms, staff and artist travel. Multiply by the page 11 factors or enter the event in the Carbon Calculator. Write the factor set and its date, the total in kg CO2e and per attendee, and your biggest data gap. Skip audience travel unless you already hold the data, and write "not yet counted".
Go deeper: Toolkit page 11; Companion pages 6 and 7; the Carbon Calculator on this site.
Co-funded by the European Union. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the European Education and Culture Executive Agency (EACEA). Neither the European Union nor EACEA can be held responsible for them.
ECHOES, project 101255350, Creative Europe CREA-CULT-2025-COOP. Training delivered by Asociația Music for Peace with Viitor Plus.